Coolant
Coolant change: once every two years.
The ratio of Ford concentrate and water for the preparation of coolant operating at temperatures down to minus 30°C | 50/ 50 % |
Valve opening pressure in the plug on the thermostat housing | 0.85 - 1.10 bar |
Thermostat
Type: with wax filling.
Opening start temperature | 85 - 89°С |
Full opening temperature | 99 - 102°С |
Water pump
Type: centrifugal, V-belt driven.
Cooling capacity
1.1 dm OHV engine3 | 5.3 dm3 |
1.1 dm OHV engine3 | 6.2 in.3 with a small heatsink or 7.2 in.3 with a large heatsink |
Engines with a displacement of 1.3 dm3 | 7.1 dm3 |