Water pump for Zetec and Zetec-E engines

            0

Withdrawal


Remove the negative terminal from the battery.

Drain the coolant from the cooling system.

Remove the toothed belt and tensioner. Disconnect the lower radiator tank hose from the pump. Unscrew the mounting bolts and remove the water pump (see fig. 3.32).



Installation


Clean the mating surfaces of the pump and motor.

Fit a new gasket to the motor and pump, and tighten the pump mounting bolts.

Further installation is carried out in the reverse order of removal. Install the toothed belt and tensioner. In this case, it is necessary to use a new tensioner spring and spring fastening pin.