Disconnect the ground wire from the battery clamp.
Remove the cap of the expansion tank of the cooling system.
Drain the fluid from the system into a container prepared in advance by unscrewing the radiator drain plug.
Loosen the bolts securing the pump drive pulley.
Loosen the generator. Loosen and remove the V-belt.
Remove the pump drive belt pulley.
Disconnect the flexible hose from the pump.
Unscrew fixing bolts and remove the pump.