Water drain panel (4-door)

            0

NameSpecification
Water drain panel
Hinge reinforcement plate

Withdrawal


1. General note
  • Remove the reinforced lock panel and rear side panel before beginning repairs.

2. Water drain panel
  • Separate spot welds (to a depth equal to twice the thickness of the panel).



Installation


1. Hinge reinforcement plate
  • Weld on.



2. Water drain panel
  • Three-layer connection zone: drill out to 5 mm (to a depth equal to the thickness of the panel). Use existing holes.
  • 1. Perform a puddling weld.
  • 2. Do a puddling weld (to a depth equal to twice the thickness of the panel).