Coupling with spring lock

            0

1.
NOTE: Select a special tool that matches the diameter of the line.


Install the special tool.
  • Install the special tool so that the inner ring can be guided into the clamp spring.



2. Press the special tool into the clamp spring.



3. Disconnect the refrigerant line.
  • Discard O-rings of circular cross-section.



4. Dock the refrigerant line.
  • Check the clamp spring for damage.
  • Carefully remove any damaged clamp springs using a thin piece of wire and install new springs.



5.
NOTE: Clean the connections using cooling oil and a lint-free cloth.


Press the indicator ring into the clamp spring.



6.
NOTE: Install new O-rings on the refrigerant lines.


NOTE: Apply clean refrigerant oil to the O-rings on the refrigerant lines before installation.


Connect the refrigerant lines.
  • Check that the clamping spring is correctly fixed.








Link to this page in different formats
HTMLTextBB Code


Visitor comments


No comments yet





Focus 2 
Focus Turnier 1 
Focus 1