Withdrawal
1. Open and unfasten the glove compartment.
2.
NOTE: Access to the servomotor is difficult.
Remove the air recirculation damper servomotor.
- Disconnect the connectors.
- Remove three screws.
Installation
1.
NOTE: The servomotor is keyed to the shaft. For this reason, the air recirculation damper can be moved to the correct position with your fingertips.
Reinstall the elements in reverse order.
2. Check the operation of the air recirculation damper.